Introducing Case2Code Use it for free! 

Home / Articles / CPT / Medicine Services and Procedures / How To Use CPT Code 99191

How To Use CPT Code 99191

This Content Might Be Outdated – Check in Our Free Code Lookup Tool

Medical codes change frequently, and using outdated information can lead to denials. Ensure you're working with the most up-to-date version of CPT Code 99191 by opening it in our free code lookup tool.

  • Instant Access to the Latest Codes
  • Detailed Code Insights & Guidelines
  • 100% Free to Use
Check the Latest Information

CPT 99191 refers to the assembly and operation of a pump with an oxygenator or heat exchanger, a critical procedure often utilized in cardiac surgeries. This service involves the meticulous setup and management of a mechanical system that takes over the functions of the heart and lungs, ensuring that blood is circulated and oxygenated outside the body. The procedure lasts for 45 minutes and may include monitoring the patient’s blood pressure and performing an electrocardiogram (ECG) to assess heart function during this time.

1. What is CPT code 99191?

CPT code 99191 represents a specialized medical service involving the assembly and operation of a mechanical pump combined with an oxygenator or heat exchanger. This procedure is essential in situations where the patient’s heart and lungs require support, such as during complex cardiac surgeries. The primary purpose of this service is to facilitate the circulation and oxygenation of blood outside the body, allowing surgeons to operate on the heart or lungs without compromising the patient’s vital functions. The procedure is performed under sterile conditions, ensuring that all components are properly assembled and functioning to maintain patient safety and efficacy of the operation.

2. Qualifying Circumstances

This CPT code can be used in specific clinical scenarios where the patient requires extracorporeal circulation support, such as during open-heart surgery or other procedures that necessitate the temporary bypass of the heart and lungs. The use of this code is appropriate when the provider is directly involved in the assembly and operation of the pump-oxygenator system for a duration of 45 minutes. Limitations may arise if the procedure is not performed under sterile conditions or if the provider does not actively manage the system throughout the operation. Inappropriate use of this code would include situations where the pump-oxygenator is not utilized, or if the provider is not directly involved in the assembly or operation of the equipment.

3. When To Use CPT 99191

CPT code 99191 should be used when a healthcare provider is responsible for the assembly and operation of a mechanical pump-oxygenator or heat exchanger during a surgical procedure. It is crucial to document the duration of the service, which must be at least 45 minutes. This code can be used in conjunction with other surgical codes that pertain to the cardiac procedure being performed, but it should not be reported alongside codes that indicate similar services or procedures that do not involve the use of a pump-oxygenator system. Proper documentation of the procedure, including patient monitoring and any complications, is essential for accurate billing and coding.

4. Official Description of CPT 99191

Official Descriptor: Assembly and operation of pump with oxygenator or heat exchanger (with or without ECG and/or pressure monitoring); 45 minutes.

5. Clinical Application

The clinical context for CPT 99191 is primarily found in cardiac surgery, where maintaining adequate blood circulation and oxygenation is critical. The procedure allows surgeons to operate on the heart while ensuring that the patient remains stable. The pump-oxygenator system effectively takes over the functions of the heart and lungs, providing oxygen-rich blood to the body and removing carbon dioxide. This service is vital for patient safety during high-risk surgeries, as it allows for complex interventions without compromising hemodynamic stability.

5.1 Provider Responsibilities

The provider’s responsibilities during this procedure include assembling the pump-oxygenator system under sterile conditions, ensuring that all components are correctly connected and functioning. This involves following established protocols and checklists to verify the sterility of components, the adequacy of electrical connections, and the functionality of the oxygenator gas supply. The provider must also prepare the priming solution, test and activate alarms, and ensure the availability of backup supplies. During the operation, the provider monitors the patient’s vital signs, including blood pressure and ECG, to ensure the patient’s safety and the effectiveness of the procedure.

5.2 Unique Challenges

One of the unique challenges associated with this service is the need for precise coordination and attention to detail during the assembly and operation of the pump-oxygenator system. Any errors in assembly or malfunction of the equipment can lead to serious complications for the patient. Additionally, the provider must be prepared to respond quickly to any changes in the patient’s condition, which may require adjustments to the pump settings or additional monitoring. The complexity of managing multiple systems simultaneously can also pose challenges, necessitating a high level of expertise and experience.

5.3 Pre-Procedure Preparations

Before the procedure, the provider must conduct thorough evaluations to ensure that all equipment is functioning correctly and that the necessary supplies are available. This includes testing the pump and oxygenator, verifying the sterility of all components, and preparing the priming solution. The provider should also review the patient’s medical history and any relevant laboratory results to anticipate potential complications during the procedure. Proper training and familiarity with the equipment are essential to ensure a smooth operation.

5.4 Post-Procedure Considerations

After the procedure, the provider must continue to monitor the patient’s vital signs and overall condition to ensure that the transition back to normal heart and lung function is successful. This may involve adjusting medications, managing fluid levels, and providing supportive care as needed. Follow-up assessments are crucial to identify any complications that may arise from the use of the pump-oxygenator system, and the provider should document all findings and interventions for continuity of care.

6. Relevant Terminology

Electrocardiogram (ECG): A test that records the electrical activity of the heart, helping to identify any irregularities or issues with heart function. It is commonly used during procedures to monitor the patient’s cardiac status.

Oxygenator: A device that adds oxygen to the blood and removes carbon dioxide, functioning as an artificial lung during procedures requiring extracorporeal circulation.

Heat Exchanger: A component that regulates the temperature of the blood being circulated, warming or cooling it as necessary to maintain the patient’s physiological balance.

Pump: A mechanical device that maintains blood flow throughout the system, effectively replacing the heart’s pumping action during surgery.

7. Clinical Examples

1. A patient undergoing open-heart surgery requires the use of a pump-oxygenator system to maintain blood circulation while the surgeon repairs a damaged valve.

2. During a lung transplant, the provider assembles the pump-oxygenator to ensure that the patient receives adequate oxygenation while the new lung is being implanted.

3. A patient with severe cardiac dysfunction is placed on a pump-oxygenator system during a high-risk surgical procedure to stabilize their condition.

4. In preparation for a complex aortic repair, the surgical team sets up the pump-oxygenator to manage blood flow and oxygenation during the operation.

5. A provider monitors a patient’s ECG and blood pressure while operating the pump-oxygenator during a lengthy cardiac surgery.

6. The pump-oxygenator is utilized in a pediatric patient undergoing heart surgery to ensure proper blood circulation and oxygenation throughout the procedure.

7. A patient with congenital heart disease requires the assembly of a pump-oxygenator system for a corrective surgical intervention.

8. During a cardiac bypass surgery, the provider operates the pump-oxygenator to maintain hemodynamic stability while the surgeon performs the necessary repairs.

9. A patient undergoing valve replacement surgery is placed on a pump-oxygenator system to facilitate the procedure and ensure adequate blood flow.

10. The provider prepares and tests the pump-oxygenator system before a scheduled cardiac surgery, ensuring all components are functioning correctly.

Free Code Lookup Tool

Free Code Lookup Tool

Find, Convert & Validate Medical Codes in Seconds

  • Advanced code search
  • Code crosswalks & mappings
  • Detailed code insights
  • History & updates
Create Free Account

No credit card required