Below is a list summarizing the CPT codes for implantable, insertable, and wearable cardiac device evaluations.
CPT Code 93260
CPT 93260 describes programming device evaluation (in person) with iterative adjustment of the implantable device to test the device’s function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for an implantable subcutaneous lead defibrillator system.
CPT Code 93261
CPT 93261 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, which includes connection, recording, and disconnection per patient encounter as an implantable subcutaneous lead defibrillator system.
CPT Code 93264
CPT 93264 describes a physician or other qualified health care professional providing remote monitoring of a wireless pulmonary artery pressure sensor for up to 30 days, including at least weekly downloads of pulmonary artery pressure recordings, interpretation(s), trend analysis, and report(s).
CPT Code 93279
CPT 93279 describes programming device evaluation (in person) with iterative adjustment of an implantable device to test the function of the device and select optimal permanent programmed values, along with analysis, review, and report by a physician or other qualified health care professional for a single lead pacemaker system or leadless pacemaker system in one cardiac chamber.
CPT Code 93280
CPT 93280 describes programming device evaluation (in person) with iterative adjustment of the implantable device to test the device’s function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a dual lead pacemaker system.
CPT Code 93281
CPT 93281 describes programming device evaluation (in person) with iterative adjustment of an implantable device to test the device’s function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a multiple lead pacemaker system.
CPT Code 93282
CPT 93282 describes programming device evaluation (in person) with iterative adjustment of the implantable device to test the device’s function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a single lead transvenous implantable defibrillator system.
CPT Code 93283
CPT 93283 describes programming device evaluation (in person) with iterative adjustment of an implantable device to test its function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a dual lead transvenous implantable defibrillator system.
CPT Code 93284
CPT 93284 describes programming device evaluation (in person) with iterative adjustment of an implantable device to test its function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a multiple lead transvenous implantable defibrillator system.
CPT Code 93285
CPT 93285 describes programming device evaluation (in person) with iterative adjustment of the implantable device to test the device’s function, selection of optimal permanent programmed values, analysis, review, and report by a physician or other qualified health care professional for a subcutaneous cardiac rhythm monitor system.
CPT Code 93286
CPT 93286 describes the evaluation, programming, analysis, review, and reporting of a single, dual, or multiple lead pacemaker system or leadless pacemaker system before or after a surgery, procedure, or test by a physician or other qualified healthcare professional.
CPT Code 93287
CPT 93287 describes the evaluation, programming, analysis, review, and reporting of a single, dual, or multiple lead implantable defibrillator system before or after a surgery, procedure, or test by a physician or other qualified health care professional.
CPT Code 93288
CPT 93288 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, which includes connection, recording, and disconnection per patient encounter; single, dual, or multiple lead pacemaker system, or leadless pacemaker system.
CPT Code 93289
CPT 93289 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, which includes connection, recording, and disconnection per patient encounter, as well as the single and dual, or multiple leads transvenous implantable defibrillator systems, including analysis of heart rhythm, derived data elements.
CPT Code 93290
CPT 93290 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, including connection, recording, and disconnection per patient encounter, as well as the analysis of one or more recorded physiologic cardiovascular data elements from all internal and external sensors of an implantable cardiovascular physiologic monitor system.
CPT Code 93291
CPT 93291 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, which includes connection, recording, and disconnection per patient encounter, as well as the subcutaneous cardiac rhythm monitor system, including heart rhythm, derived data analysis.
CPT Code 93292
CPT 93292 describes the evaluation of an interrogation device (in person) with analysis, review, and report by a physician or other qualified health care professional, which includes connection, recording, and disconnection per patient encounter as the use of a wearable defibrillator system.
CPT Code 93293
CPT 93293 describes transtelephonic rhythm strip pacemaker evaluation(s) of a single, dual, or multiple lead pacemaker system, including recording with and without magnet application with analysis, review, and report(s) by a physician or other qualified health care professional, up to 90 days.
CPT Code 93294
CPT 93294 describes the evaluation of a remote interrogation device, up to 90 days, for a single, dual, or multiple lead pacemaker system, or leadless pacemaker system, with interim analysis, review(s), and report(s) by a physician or other qualified health care professional.
CPT Code 93295
CPT 93295 describes the evaluation of a remote interrogation device for up to 90 days for a single, dual, or multiple lead implantable defibrillator system with interim analysis, reviews, and reports by a physician or other qualified health care professional.
CPT Code 93296
CPT 93296 describes the evaluation of a remote interrogation device, up to 90 days, for a single, dual, or multiple lead pacemaker system, leadless pacemaker system, or implantable defibrillator system, with remote data acquisition, receipt of transmissions, technician review, technical support, and distribution of results.
CPT Code 93297
CPT 93297 describes the evaluation of a remote interrogation device for up to 30 days, including analyzing one or more recorded physiologic cardiovascular data elements from all internal and external sensors, analysis, reviews, and reports by a physician or other qualified health care professional.
CPT Code 93298
CPT 93298 describes the evaluation of a remote interrogation device for up to 30 days, including the analysis of recorded heart rhythm data, analysis, reviews, and reports by a physician or other qualified healthcare professional.