Coding Ahead
CasePilot
Medical Coding Assistant
CaseConsultant
Instant Email Coding Consultant
Case2Code
Search and Code Lookup Tool
CareerCenter
Medical Coding Job Board
Log in Register free account

Need help choosing the right code?

Ask CasePilot about procedures, modifiers, bundling, and coding guidance.

Try CasePilot

Official Description

Pure tone audiometry (threshold), automated; air only

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

Automated pure tone audiometry is a specialized hearing evaluation procedure that utilizes a computerized system to assess an individual's hearing capabilities. This method involves the use of ambient noise microphones strategically positioned near the patient's ears to capture sound levels accurately. During the test, ear inserts are placed within the ear, which are connected to transducers and a bone oscillator located outside the ear. It is important to note that these ear inserts do not completely block the ear canal, allowing for a more natural assessment of hearing. The automated audiometry device is programmed to conduct specific tests aimed at measuring hearing sensitivity. The primary objective of this procedure is to determine the pure tone thresholds, which represent the softest sounds that a patient can hear at least 50 percent of the time. The results of the test are visually represented on a computer screen, providing a graphic depiction of the patient's hearing sensitivity. This procedure is denoted by the CPT® code 0208T, which specifically refers to the performance of automated pure tone air audiometry testing. In contrast, CPT® code 0209T encompasses both air and bone pure tone audiometry, where the latter involves transmitting sound signals through the bones of the skull to evaluate auditory function further.

© Copyright 2026 Coding Ahead. All rights reserved.

1. Indications

The automated pure tone audiometry procedure is indicated for the assessment of hearing sensitivity in patients who may be experiencing hearing loss or other auditory issues. This evaluation is essential for diagnosing conditions related to hearing impairment and determining the appropriate course of treatment or intervention. The following conditions may warrant the use of this procedure:

  • Hearing Loss Patients presenting with symptoms of hearing loss, which may include difficulty understanding speech, asking for repetition, or an overall decrease in auditory perception.
  • Auditory Processing Disorders Individuals suspected of having auditory processing disorders, where the brain has difficulty interpreting sounds, may benefit from this testing.
  • Monitoring Hearing Changes Patients undergoing treatment for conditions that may affect hearing, such as ototoxic medications or chronic ear infections, may require regular monitoring of their hearing sensitivity.
  • Pre-Employment Screening Automated pure tone audiometry may be utilized in occupational health settings to screen employees for hearing capabilities, particularly in environments with high noise exposure.

2. Procedure

The automated pure tone audiometry procedure involves several key steps to ensure accurate assessment of hearing sensitivity. The following outlines the procedural steps:

  • Step 1: Preparation The patient is positioned comfortably in a sound-treated environment to minimize external noise interference. Ambient noise microphones are placed near the patient's ears to accurately capture sound levels during the testing process.
  • Step 2: Ear Insert Placement Ear inserts are carefully placed in the patient's ears. These inserts are designed to connect to transducers and a bone oscillator, which are positioned outside the ear. It is crucial that the ear inserts do not completely occlude the ear canal, allowing for a natural hearing assessment.
  • Step 3: Programming the Device The automated audiometry device is programmed with the desired testing parameters. This includes setting the frequency and intensity levels for the pure tone sounds that will be presented to the patient.
  • Step 4: Conducting the Test The automated system conducts the pure tone audiometry test by presenting a series of tones at various frequencies and intensities. The patient is instructed to respond when they hear a sound, allowing the system to determine the softest sound they can detect at least 50 percent of the time.
  • Step 5: Data Representation Upon completion of the testing, the computer generates a graphic representation of the patient's hearing sensitivity, displaying the pure tone thresholds for each frequency tested. This visual output aids in the interpretation of the results and assists healthcare professionals in making informed decisions regarding the patient's auditory health.

3. Post-Procedure

After the automated pure tone audiometry procedure, patients may be advised to avoid exposure to loud noises for a short period to prevent any potential temporary threshold shifts. The results of the audiometry test will be reviewed by a qualified healthcare professional, who will discuss the findings with the patient. Depending on the outcomes, further evaluation or intervention may be recommended, which could include additional audiological assessments, referrals to specialists, or recommendations for hearing aids or other assistive devices. Patients should also be informed about the importance of regular hearing evaluations, especially if they have risk factors for hearing loss.

Short Descr AUDIOMETRY AIR ONLY
Medium Descr PURE TONE AUDIOMETRY AUTOMATED AIR ONLY
Long Descr Pure tone audiometry (threshold), automated; air only
Status Code Carriers Price the Code
Global Days XXX - Global Concept Does Not Apply
PC/TC Indicator (26, TC) 3 - Technical Component Only Code
Multiple Procedures (51) 0 - No payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 0 - Payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 0 - Co-surgeons not permitted for this procedure.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator STV-Packaged Codes
Type of Service (TOS) 9 - Other Medical Items or Services
Berenson-Eggers TOS (BETOS) O1F - Hearing and speech services
MUE 1
CCS Clinical Classification 220 - Ophthalmologic and otologic diagnosis and treatment
Date
Action
Notes
2011-01-01 Added First appearance in code book.
2010-01-01 Added Code implemented.
Code
Description
Code
Description
CasePilot

Get instant expert-level medical coding assistance.

Ask about:
CPT Codes Guidelines Modifiers Crosswalks NCCI Edits Compliance Medicare Coverage
Example: "What is CPT code 99213?" or "Guidelines for E/M services"