Bone material quality testing by microindentation(s) is a specialized invasive diagnostic procedure aimed at assessing the mechanical properties of bone, particularly focusing on the stiffness of the cortical bone. This test is performed using a hand-held micro-indentation device that involves inserting a sterile probe through the skin to create a series of indentations or microscopic fractures in the tibia. The primary objective of this testing is to provide valuable insights into the bone's mechanical characteristics, which can significantly influence the outcomes of orthopedic implant procedures. Understanding the stiffness of the bone is crucial for surgeons, as it informs them about the amount of force required to properly seat an implant. For instance, stiffer bones necessitate greater force during implantation, while more pliant bones may require less force but could lead to a higher risk of implant loosening. This procedure is particularly relevant for elderly patients, who often exhibit more porous bones with diminished stiffness, thereby increasing the likelihood of complications such as a loose fit of prosthetic joints or fractures during the implantation process. The testing process involves careful positioning of the patient, administration of local anesthetic, and precise execution of indentation measurements, followed by a comparison of these measurements against a reference material to derive a bone material strength index score.
© Copyright 2026 Coding Ahead. All rights reserved.
The bone material quality testing by microindentation(s) is indicated for the following conditions:
The procedure for bone material quality testing by microindentation(s) involves several key steps to ensure accurate measurement of bone stiffness.
After the completion of the bone material quality testing, the patient may experience some localized discomfort at the site of the probe insertion, which typically resolves quickly. There are no specific post-procedure care instructions mentioned; however, it is advisable for the patient to monitor the site for any signs of infection or unusual swelling. The results of the test, reported as a bone material strength index score, will be used by the healthcare provider to inform further clinical decisions regarding orthopedic interventions and to assess the overall bone health of the patient.
| Short Descr | B1 MATRL QUAL TST MCRIND TIB | Medium Descr | BONE MATRL QUALITY TST BY MICROINDENTATION TIBIA | Long Descr | Bone-material quality testing by microindentation(s) of the tibia(s), with results reported as a score | Status Code | Carriers Price the Code | Global Days | XXX - Global Concept Does Not Apply | PC/TC Indicator (26, TC) | 0 - Physician Service Code | Multiple Procedures (51) | 0 - No payment adjustment rules for multiple procedures apply. | Bilateral Surgery (50) | 0 - 150% payment adjustment for bilateral procedures does NOT apply. | Physician Supervisions | 09 - Concept does not apply. | Assistant Surgeon (80, 82) | 0 - Payment restriction for assistants at surgery applies to this procedure... | Co-Surgeons (62) | 0 - Co-surgeons not permitted for this procedure. | Team Surgery (66) | 0 - Team surgeons not permitted for this procedure. | Diagnostic Imaging Family | 99 - Concept Does Not Apply | APC Status Indicator | Non-Covered Service, not paid under OPPS | Berenson-Eggers TOS (BETOS) | none | MUE | 1 |
|
Date
|
Action
|
Notes
|
|---|---|---|
| 2020-01-01 | Added | First appearance in code book. |
| 2019-07-01 | Added | Code added. |
Get instant expert-level medical coding assistance.