Official Description

Transcatheter removal and replacement of permanent dual-chamber leadless pacemaker, including imaging guidance (eg, fluoroscopy, venous ultrasound, right atrial angiography, right ventriculography, femoral venography) and device evaluation (eg, interrogation or programming), when performed; right atrial pacemaker component

© Copyright 2026 American Medical Association. All rights reserved.

Common Language Description

The CPT® Code 0802T refers to the transcatheter removal and replacement of a permanent dual-chamber leadless pacemaker, specifically focusing on the right atrial pacemaker component. A leadless pacemaker is a compact device that functions as a pulse generator, equipped with a built-in battery and electrode, designed to regulate heart rhythms without the need for traditional leads. This procedure is typically indicated when the battery life of the pacemaker component has been depleted, necessitating its replacement. The process involves accessing the femoral vein, utilizing imaging guidance techniques such as fluoroscopy, venous ultrasound, and angiography to ensure accurate placement and retrieval of the pacemaker. The procedure is intricate, requiring careful navigation through the venous system to capture and replace the pacemaker while ensuring proper functionality through device evaluation, which may include interrogation or programming. This code is specifically applicable when only the right atrial component is addressed during the session, distinguishing it from similar procedures that may involve the right ventricular component.

© Copyright 2026 Coding Ahead. All rights reserved.

1. Indications

The procedure associated with CPT® Code 0802T is indicated for the following conditions:

  • Battery Depletion Replacement of the leadless pacemaker is performed when the battery life of the pacemaker component is depleted.

2. Procedure

The procedure for the transcatheter removal and replacement of the right atrial component of a dual-chamber leadless pacemaker involves several detailed steps:

  • Step 1: Preparation The groin area is prepped and draped to maintain a sterile environment. Access to the femoral vein is established, which is crucial for the subsequent steps of the procedure.
  • Step 2: Accessing the Femoral Vein A guidewire is placed into the femoral vein, and venous ultrasound may be utilized to visualize the anatomy, ensuring accurate access to the vein.
  • Step 3: Insertion of Femoral Sheath A femoral sheath is placed into the vein, followed by incremental dilation to accommodate the retrieval introducer.
  • Step 4: Placement of Retrieval Introducer The leadless pacemaker retrieval introducer is inserted into the vein, and the guidewire is subsequently removed to allow for the placement of the retrieval catheter.
  • Step 5: Catheter Advancement Under fluoroscopic guidance, the retrieval catheter is advanced through the inferior vena cava into the right atrium, where it is positioned to capture the leadless pacemaker using a snare technique.
  • Step 6: Retrieval of Pacemaker Once the pacemaker is securely captured, the retrieval catheter, along with the pacemaker, is withdrawn from the body.
  • Step 7: Insertion of Replacement Pacemaker A steerable delivery catheter, which contains an integrated guide catheter and the preloaded replacement leadless pacemaker, is threaded through the introducer and advanced into the right atrium.
  • Step 8: Testing the Pacemaker The new pacemaker is tested by sending signals from an external programmer to ensure it is functioning correctly. Mapping is performed to ensure accurate placement.
  • Step 9: Deployment of Pacemaker The leadless pacemaker is deployed and positioned securely against the endocardium. It is undocked but remains tethered during initial testing.
  • Step 10: Confirmation of Functionality Pacing capture threshold, impedance, and sensing tests are conducted to confirm the adequacy of the implantation site within the atrium. Any necessary repositioning and retesting are performed before the tether is released.
  • Step 11: Withdrawal of Delivery Catheter The delivery catheter is withdrawn after the tether is released, completing the replacement process for the right atrial component.

3. Post-Procedure

Post-procedure care involves monitoring the patient for any complications and ensuring the proper functioning of the newly implanted pacemaker. Patients may require follow-up evaluations to assess the pacemaker's performance and to confirm that the implantation site is healing appropriately. Additional imaging or device interrogation may be performed to ensure that the pacemaker is operating within the expected parameters.

Short Descr TCAT RMV&RPL2CHMB LDLS PM RA
Medium Descr TCAT RMVL&RPLCMT PERM 2CHMBR LDLS PM R ATR CMPNT
Long Descr Transcatheter removal and replacement of permanent dual-chamber leadless pacemaker, including imaging guidance (eg, fluoroscopy, venous ultrasound, right atrial angiography, right ventriculography, femoral venography) and device evaluation (eg, interrogation or programming), when performed; right atrial pacemaker component
Status Code Carriers Price the Code
Global Days YYY - Carrier Determines Whether Global Concept Applies
PC/TC Indicator (26, TC) 0 - Physician Service Code
Multiple Procedures (51) 2 - Standard payment adjustment rules for multiple procedures apply.
Bilateral Surgery (50) 0 - 150% payment adjustment for bilateral procedures does NOT apply.
Physician Supervisions 09 - Concept does not apply.
Assistant Surgeon (80, 82) 1 - Statutory payment restriction for assistants at surgery applies to this procedure...
Co-Surgeons (62) 2 - Co-surgeons permitted and no documentation required if the two- specialty requirement is met.
Team Surgery (66) 0 - Team surgeons not permitted for this procedure.
Diagnostic Imaging Family 99 - Concept Does Not Apply
APC Status Indicator Hospital Part B services paid through a comprehensive APC
Berenson-Eggers TOS (BETOS) none
MUE 1

This is a primary code that can be used with these additional add-on codes.

93662 Addon Code MPFS Status: Carrier Priced APC N PUB 100 CPT Assistant Article Intracardiac echocardiography during therapeutic/diagnostic intervention, including imaging supervision and interpretation (List separately in addition to code for primary procedure)
Date
Action
Notes
2024-01-01 Added First appearance in code book.