How To Use CPT Code 0522T

CPT 0522T describes the programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing. This article will cover the official description, procedure, qualifying circumstances, appropriate usage, documentation requirements, billing guidelines, historical information, and examples.

1. What is CPT Code 0522T?

CPT 0522T can be used to describe the programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing. This code is used when a provider tests the function of the device and selects optimal permanent programmed values through iterative adjustment using a programming device. The provider performs this evaluation in person and prepares a report based on the results.

2. Official Description

The official description of CPT code 0522T is: ‘Programming device evaluation (in person) with iterative adjustment of the implantable device to test the function of the device and select optimal permanent programmed values with analysis, including review and report, wireless cardiac stimulator for left ventricular pacing.’

3. Procedure

  1. The provider uses a programming device that is a component of the wireless cardiac stimulator system to test the function of the device.
  2. Based on the results of the initial test, the provider makes iterative adjustments to the programming of the implantable device.
  3. The provider repeats the testing and adjustment process as many times as necessary until they are satisfied with the programming.
  4. Once the optimal permanent programmed values are selected, the provider analyzes the results and prepares a report.

4. Qualifying circumstances

CPT 0522T is used for patients who require evaluation and adjustment of a wireless cardiac stimulator system for left ventricular pacing. This code is specifically for programming device evaluation performed in person. The provider must use a programming device that is a component of the wireless cardiac stimulator system. It is important to note that CPT 0522T should not be reported in conjunction with codes 0515T, 0516T, 0517T, 0518T, 0519T, 0520T, or 0521T.

5. When to use CPT code 0522T

CPT code 0522T should be used when a provider performs a programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing in person. This code should not be used in conjunction with other specific codes related to cardiac device implantation, analysis, and removal procedures.

6. Documentation requirements

To support a claim for CPT 0522T, the provider must document the following information:

  • Details of the programming device evaluation, including the specific adjustments made to the implantable device
  • Results of the evaluation and analysis
  • Selection of optimal permanent programmed values
  • Preparation of a report based on the evaluation and analysis
  • Date and duration of the evaluation
  • Signature of the provider performing the evaluation

7. Billing guidelines

When billing for CPT 0522T, ensure that the evaluation and adjustment of the wireless cardiac stimulator system for left ventricular pacing are performed in person. Do not report CPT 0522T in conjunction with codes 0515T, 0516T, 0517T, 0518T, 0519T, 0520T, or 0521T. It is important to follow the specific guidelines and instructions provided by the payer to ensure accurate billing and reimbursement.

8. Historical information

CPT 0522T was added to the Current Procedural Terminology system on January 1, 2019. There have been no updates or changes to the code since its addition.

9. Examples

  1. A cardiologist performs a programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing, adjusting the programming to optimize the device’s function and preparing a report based on the analysis.
  2. An electrophysiologist tests and adjusts the programming of a wireless cardiac stimulator system for left ventricular pacing, repeating the process until optimal permanent programmed values are selected and documenting the results in a report.
  3. A cardiac surgeon evaluates the function of a wireless cardiac stimulator system for left ventricular pacing, making iterative adjustments to the programming and analyzing the results to determine the optimal settings for the patient.
  4. A cardiac nurse specialist performs a programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing, documenting the adjustments made and preparing a report based on the analysis of the device’s function.
  5. An interventional cardiologist tests and adjusts the programming of a wireless cardiac stimulator system for left ventricular pacing, reviewing the results and selecting optimal permanent programmed values to improve the patient’s cardiac function.
  6. A cardiac electrophysiologist evaluates the function of a wireless cardiac stimulator system for left ventricular pacing, making iterative adjustments to the programming and preparing a detailed report on the analysis and findings.
  7. A cardiac technician performs a programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing, documenting the adjustments made and analyzing the results to ensure optimal functioning of the device.
  8. An implantable device specialist tests and adjusts the programming of a wireless cardiac stimulator system for left ventricular pacing, reviewing the results and preparing a comprehensive report on the analysis and programming settings.
  9. A cardiac nurse practitioner performs a programming device evaluation for a wireless cardiac stimulator system for left ventricular pacing, documenting the adjustments made and analyzing the results to optimize the device’s function for the patient.
  10. A cardiac electrophysiology technologist tests and adjusts the programming of a wireless cardiac stimulator system for left ventricular pacing, repeating the process until optimal permanent programmed values are selected and preparing a detailed report on the analysis and findings.

Similar Posts