CPT Codes For Long-Term EEG Monitoring

Below is a list summarizing the CPT codes for long-term EEG monitoring.

CPT Code 95705

CPT 95705 describes a technical description of an Electroencephalogram (EEG) without video, reviewed by an EEG technologist for 2-12 hours without monitoring.

CPT Code 95706

CPT 95706 describes an Electroencephalogram (EEG) technical description by an EEG technologist, with intermittent monitoring and maintenance, without video, and review of data for 2-12 hours.

CPT Code 95707

CPT 95707 describes an Electroencephalogram (EEG) technical description by an EEG technologist, with continuous, real-time monitoring and maintenance, without video, and review of data for 2-12 hours.

CPT Code 95708

CPT 95708 describes a technical description of an Electroencephalogram (EEG) review of data, without video, by an EEG technologist, for each increment of 12-26 hours, unmonitored.

CPT Code 95709

CPT 95709 describes a technical description of an Electroencephalogram (EEG) data review, with intermittent monitoring and maintenance, each increment of 12-26 hours without video.

CPT Code 95710

CPT 95710 describes a technical description of an Electroencephalogram (EEG) data review, with continuous, real-time monitoring and maintenance, each increment of 12-26 hours without video.

CPT Code 95711

CPT 95711 describes a procedure for an electroencephalogram with video (VEEG), data review, technical description by an EEG technologist, and unmonitored recording for 2-12 hours.

CPT Code 95712

CPT 95712 describes a procedure involving an electroencephalogram with video (VEEG), data review, technical description by an EEG technologist, and intermittent monitoring and maintenance for 2-12 hours.

CPT Code 95713

CPT 95713 describes a procedure involving an electroencephalogram with video (VEEG), data review, technical description by an EEG technologist, and 2-12 hours of continuous, real-time monitoring and maintenance.

CPT Code 95714

CPT 95714 describes a review of data from an electroencephalogram with video (VEEG) by an EEG technologist, each increment of 12-26 hours, unmonitored.

CPT Code 95715

CPT 95715 describes a review of data from an electroencephalogram with video (VEEG) by an EEG technologist, with intermittent monitoring and maintenance over each increment of 12-26 hours.

CPT Code 95716

CPT 95716 describes a review of data from an electroencephalogram with video (VEEG) by an EEG technologist, with continuous, real-time monitoring and maintenance for each increment of 12-26 hours.

CPT Code 95717

CPT 95717 describes a physician or other qualified health care professional’s review of a continuous electroencephalogram (EEG) recording, analysis of spike and seizure detection, interpretation, and report, for 2-12 hours without video.

CPT Code 95718

CPT 95718 describes a physician or other qualified health care professional review of a continuous electroencephalogram (EEG) recording, analysis of spike and seizure detection, interpretation, and report, with 2-12 hours of EEG recording and video (VEEG).

CPT Code 95719

CPT 95719 describes a continuous recording of an Electroencephalogram (EEG) with a physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, each increment of greater than 12 hours, up to 26 hours of EEG recording, interpretation and report after every 24 hours; without video.

CPT Code 95720

CPT 95720 describes a continuous recording of an Electroencephalogram (EEG) with a physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, each increment of greater than 12 hours, up to 26 hours of EEG recording, interpretation and report after every 24 hours; with video (VEEG).

CPT Code 95721

CPT 95721 describes a complete electroencephalogram (EEG) study, including continuous recording, physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, interpretation, and summary report, with greater than 36 hours, up to 60 hours of EEG recording, without video.

CPT Code 95722

CPT 95722 describes a complete electroencephalogram (EEG) study with greater than 36 hours, up to 60 hours of EEG recording, with video (VEEG), including continuous recording, physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, interpretation, and summary report.

CPT Code 95723

CPT 95723 describes a complete electroencephalogram (EEG) study, including continuous recording, physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, interpretation, and summary report, with greater than 60 hours, up to 84 hours of EEG recording, without video.

CPT Code 95724

CPT 95724 describes a complete electroencephalogram (EEG) study with greater than 60 hours, up to 84 hours of EEG recording, with video (VEEG), including continuous recording, physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, interpretation, and summary report.

CPT Code 95725

CPT 95725 describes a complete electroencephalogram (EEG) study, including continuous recording, physician or other qualified health care professional review of recorded events, analysis of spike and seizure detection, interpretation, and summary report, with greater than 84 hours of EEG recording, without video.

CPT Code 95726

CPT 95726 describes a complete electroencephalogram (EEG) study with more than 84 hours of EEG recording, including continuous recording, physician or other qualified health care professional review of recorded events, spike and seizure detection analysis, interpretation, and summary report, with video (VEEG).